Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: https://repo.snau.edu.ua:8080/xmlui/handle/123456789/12110
Повний запис метаданих
Поле DCЗначенняМова
dc.contributor.authorLoboda, V. B.-
dc.contributor.authorZubko, V. M.-
dc.contributor.authorKhursenko, S. M.-
dc.contributor.authorKravchenko, V. O.-
dc.contributor.authorChepizhnyi, A. V.-
dc.contributor.authorЛобода, В. Б.-
dc.contributor.authorЗубко, В. М.-
dc.contributor.authorХурсенко, С. М.-
dc.contributor.authorКравченко, В. О.-
dc.contributor.authorЧепіжний, А. В.-
dc.date.accessioned2024-08-05T11:12:17Z-
dc.date.available2024-08-05T11:12:17Z-
dc.date.issued2023-
dc.identifier.citationX-Ray Spectral Microanalysis of Copper-Nickel Thin Films Alloys [Electronic resource] / V. Loboda, V. Zubko, S. Khursenko [and other] // Journal of Nano- and Electronic Physics. – 2023. – Т. 15, № 5. – Р. 05014-5.uk_UA
dc.identifier.urihttps://repo.snau.edu.ua:8080/xmlui/handle/123456789/12110-
dc.descriptionУ статті наведено результати дослідження елементного складу плівок сплавів CuNi методом рентгенівського мікроаналізу (рентгенівський мікроаналізатор на базі спектрометра з дисперсією з енергії, що входить до складу растрового електронного мікроскопа РЕМ-103-01). Плівки сплавів товщинами 30-150 нм були отримані одночасним роздільним випаровуванням компонент (мідь та нікель) у вакуумі 10 – 4 Па. Мідь випаровувалася зі стрічки з вольфрамової фольги товщиною 0,05 мм. Нікель випаровувався електронно-променевим способом за допомогою електронної діодної гармати. Швидкість конденсації становила 0,5-1,5 нм/с. Чистота випаровуваних металів становила щонайменше 99,98 %. Розрахунковий склад концентрацій компонентів зразків змінювався в широкому діапазоні. Характеристичний рентгенівський спектр речовини плівки порушувався при скануванні електронним пучком ділянки плівки розмірами 300 х 300 мкм; для товстіших плівок розмір ділянки сканування становив 1 х 1 мкм. Як еталони при проведенні кількісних вимірювань елементного складу плівок сплавів певної товщини використовувалася тонкі плівки Ni такої ж товщини. Результати рентгенівського мікроаналізу свідчать про високу чистоту плівок. Зіставлення розрахункових концентрацій сплавів та результатів вимірювань рентгенівським мікроаналізом показало, що в області товщин плівок d<100 нм розбіжність становить близько 10 %, знижуючись до 1-3 % при товщинах зразків d > 100 нм.uk_UA
dc.description.abstractThe article presents the results of studying the elemental composition of films of CuNi alloys by X-ray microanalysis (an X-ray microanalyzer based on an energy-dispersive spectrometer, which is part of the REM-103-01 scanning electron microscope). Alloy films 30-150 nm thick were obtained by simultaneous separate evaporation of the components (copper and nickel) in a vacuum of 10 –4 Pa. Copper was evaporated from a tungsten foil ribbon 0.05 mm thick. Nickel was evaporated by the electron beam method using an electron diode gun. The condensation rate was 0.5-1.5 nm/s. The purity of the evaporated metals was no less than 99.98 %. The calculated composition of the concentrations of the sample components varied over a wide range. The characteristic X-ray spectrum of the film substance was excited by scanning a section of the film with dimensions of 300 x 300 μm with an electron beam; for thicker films, the size of the scanning area was 1 x 1 μm. Thin Ni films of the same thickness were used as standards for quantitative measurements of the elemental composition of alloy films of a certain thickness. The results of X-ray microanalysis indicate a high purity of the films. Comparison of the calculated concentrations of alloys and the results of measurements by X-ray microanalysis showed that in the region of film thicknesses d < 100 nm, the discrepancy is about 10 %, decreasing to 1 – 3 % for sample thicknesses d>100 nm.uk_UA
dc.language.isootheruk_UA
dc.subjectX-Ray Spectral Microanalysisuk_UA
dc.subjectThin Filmsuk_UA
dc.subjectCopper-Nickel Alloysuk_UA
dc.subjectрентгеноспектральний мікроаналізuk_UA
dc.subjectтонкі плівкиuk_UA
dc.subjectмідно-нікелеві сплавиuk_UA
dc.titleX-Ray Spectral Microanalysis of Copper-Nickel Thin Films Alloysuk_UA
dc.title.alternativeРентгеноспектральний мікроаналіз тонких плівок мідно-нікелевих сплавівuk_UA
dc.typeOtheruk_UA
Розташовується у зібраннях:Статті, тези доповідей

Файли цього матеріалу:
Файл Опис РозмірФормат 
Кравченко 1.pdf597 kBAdobe PDFПереглянути/Відкрити


Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.